SM12L-A2-IOP

SKU : SM12L-A2-IOP

CONSTRUCTION

1. Optical Fiber: 12 Core 250um SM G657.A2         Inner Jacket Diameter: 3.5±0.1mm
2. Flexible Stainless Steel Metal Tube  Diameter: 3.5±0.1mm   Material:SUS-202 Sprial
3. Kevlar Yarn & Water Block Tape
4. Outer Jacket: Color: BLACK UV         Cable Diameter: 5.5±0.2mm
5.Cable Legend:P2P nanoFIBER OPTIC ARMORED PLENUM INDOOR/OUTDOOR CABLE SM12L-A2-IOP 12F OS2 G.657.A2 YYWW

FIBER OPTIC PARAMETERS

Optical Fiber Type UNIT SM G.657.A2
Wave Length nm 1310/1550
Attenuation dB/Km 0.5/0.4

MECHANICAL PARAMETERS

Performance Long-Term Short-Term
Max. Tension(N) 100 200
Max. Crush Resistance (N/100mm) 1000 3000
Min. Bend Radius 20D (Dynamic) 10D (Static)
Storage and Opterating Temperature -20℃ ~ + 60℃

Optical Fiber Specification IEC 60793-2-50 type B1.3/B6

Characteristics Conditions Specified Values Units
Optical Characteristics
Attenuation 1310 nm
1383 nm (after H2-aging)
1460 nm
1490 nm
1550 nm
1625 nm
⩽0.35
⩽0.35
⩽0.25
⩽0.23
⩽0.21
⩽0.23
[dB/km]
[dB/km]
[dB/km]
[dB/km]
[dB/km]
[dB/km]
Attenuation vs. Wavelength 1285~ 1330 nm ⩽0.03 [dB/km]
Max. α difference 1525 ~ 1575 nm 0.02 [dB/km]
Zero dispersion wavelength 1300~ 1324 [nm]
Zero dispersion slope ⩽0.092 [ps/(nm2 • km)]
PMD
Maximum Individual Fibre ⩽0.1 [ps/√Km]
Link Design Value (M=20,Q=0.01 %) ⩽0.06 [ps/√Km]
Typical value 0.04 [ps/√Km]
Cable cutoff wavelength λcc ⩽1260 [nm]
Mode field diameter (MFD) 1310 nm
1550 nm
8.4 ~ 9.2
9.3~ 10.3
[µm]
[µm]
Effective group index of refraction (Nett) 1310 nm
1550 nm
1.466
1.467
Point discontinuities 1310 nm
1550 nm
⩽0.05
⩽0.05
[dB]
[dB]
Geometrical Characteristics
Cladding diameter 125.0±0.7 [µm]
Cladding non-circularity ⩽0,7 [%]
Coating diameter 245±5 [µm]
Coating-cladding concentricity error ⩽ 12.0 [µm]
Coating non-circularity ⩽6,0 [%]
Core-cladding concentricity error ⩽0,5 [µm]
Curl (radius) ⩾4 [m]
Delivery length 2.1 to 50.4 [km/reel]
Environmental Characteristics (1310 nm, 1550 nm & 1625 nm)
Temperature dependence Induced attenuation at -60°C to +85°C ⩽0,05 [dB/km]
Temperature-humidity cycling Induced attenuation at -10°C to +85°C, 98% RH ⩽0,05 [dB/km]
Watersoak dependence Induced attenuation at 23°C, for 30 days ⩽0,05 [dB/km]
Damp heat dependence Induced attenuation at 85°C and 85% RH, for 30 days ⩽0,05 [dB/km]
Dry heat aging at 85°C, for 30 days ⩽0,05 [dB/km]
Mechanical Specification
Proof test ⩾9.0
⩾1.0
⩾100
[N]
[%]
[kpsi]
Macro-bend induced attenuation
10 turns around a mandrel of 15 mm radius
10 turns around a mandrel of 15 mm radius
1 turn around a mandrel of 10 mm radius
1 turn around a mandrel of 10 mm radius
1 turn around a mandrel of 7.5 mm radius
1 turn around a mandrel of 7.5 mm radius
1550 nm
1625 nm
1550 nm
1625 nm
1550 nm
1625 nm
⩽0,03
⩽0, 1
⩽0.1
⩽0.2
⩽0,2
⩽0,5
[dB]
[dB]
[dB]
[dB]
[dB]
[dB]
Coating strip force typical average torce
peak force
1.5
⩾1.3 ⩽8,9
[N]
[N]
Dynamic stress corrosion susceptibility parameter (nd, typical) 27

fibre optics

Donwload PDF

fibre optics

Donwload PDF

SKU: SM12L-A2-IOP Categories: ,